4.5 Article

Siloxane-Crown Ether Polyamide Based Electrode for Electrochemical Determination of Lead(II) in Aqueous Solution

期刊

ELECTROANALYSIS
卷 24, 期 10, 页码 1995-2004

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.201200190

关键词

Crown ether polyamide; Lead(II); Stripping voltammetry

资金

  1. European Social Fund Cristofor I. Simionescu Postdoctoral Fellowship Programme, Sectoral Operational Programme Human Resources Development [POSDRU/89/1.5/S/55216]

向作者/读者索取更多资源

A siloxane-crown ether polyamide copolymer (PDMS-PA-DB18C6) was electrochemically investigated for fabrication of lead-sensitive electrodes for trace analysis in aqueous solutions. The PDMS-PA-DB18C6 electrodes were successfully evaluated for anodic stripping voltammetric determination of lead(II) as a promising alternative for the detection of lead at ppb levels. By a judicious choice of the deposition time, electrolyte concentration and pulse amplitude, good analytical performance of the developed sensor could be achieved, with a linear response in the range of 20700 ppb, when LOD of 3.5 ppb could be attained. This method showed a good degree of selectivity and sensitivity for lead, suitable for the determination of Pb2+ in wastewater sample.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据