4.4 Article

Evaluating the use of spatially varying versus bulk average 3D vegetation structural inputs to modelled evapotranspiration within heterogeneous land cover types

期刊

ECOHYDROLOGY
卷 7, 期 6, 页码 1545-1559

出版社

WILEY
DOI: 10.1002/eco.1477

关键词

evapotranspiration modelling; LiDAR; eddy covariance; vegetation structure; boreal; wetland; aspen

资金

  1. NSERC Discovery Grant
  2. NSERC Collaborative Research and Development Grant [HEAD2]
  3. NSERC Research Tools and Instrument Grant
  4. Cumulative Environmental Managers Association (CEMA)
  5. NERC [NE/G000360/1] Funding Source: UKRI
  6. Natural Environment Research Council [NE/G000360/1] Funding Source: researchfish

向作者/读者索取更多资源

The Western Boreal Plain of north-central Alberta is prone to water-deficit conditions and is hydrologically sensitive to changes in climate, natural resource extraction and disturbance. Accurate measurement and modelling of the main components of the water balance are important for ecosystem and reclamation management; however, the lack of hydro-meteorological instrumentation found within different land cover types makes quantification of changes to the water balance difficult over large areas. Remote sensing data can provide spatial estimates of land cover distribution and leaf area index (LAI) used as inputs into land surface models. However, land surface models can often suffer from inaccuracies as a result of spatial (coarse pixel) and temporal (discrete acquisition) resolutions, mis-classification and inaccurate representation of LAI using remote sensing data. This study uses high-resolution (1mx1m) Light Detection and Ranging-derived vegetation parameters (land cover type, LAI and 3D vegetation frictional influences on air movement) as inputs into the Penman-Monteith evapotranspiration (ET) model along with measured hydro-meteorological variables. Comparison with eddy covariance (EC) measurements indicated that spatially explicit ET estimates at 1m resolution (over a 5kmx5km study area) provided better estimates compared with bulk average ET estimates per land cover type. ET estimates scaled using spatially variable vegetation inputs only underestimated measured fluxes by 2% and 3% at 225 and 3m EC instrumentation towers, respectively. Bulk averaged ET estimates underestimated measured ET by 5% at the 3m tower and overestimated EC by 7% at the 225m EC tower. Over coarser scales, the error associated with bulk input parameters can lead to error in overall water balance estimation. Copyright (c) 2014 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据