4.3 Article

Correlation of MIC value and disk inhibition zone diameters in clinical Legionella pneumophila serogroup 1 isolates

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.diagmicrobio.2013.03.001

关键词

Legionella pneumophila; MDcorr; Quinolones; Macrolides; Disk diffusion

资金

  1. Regional Laboratory of public Health, Haarlem

向作者/读者索取更多资源

Objectives: Routine use of disk diffusion tests for detecting antibiotic resistance in Legionella pneumophila has not been described. The goal of this study was to determine the correlation of MIC values and inhibition zone diameter (MDcorr) in clinical L pneumophila isolates. Methods: Inhibition zone diameter of 183 L pneumophila clinical isolates were determined for ten antimicrobials. Disk diffusion results were correlated with MICs as determined earlier with E-tests. Results: Overall the correlation of MIC values and inhibition zone diameters (MDcorr) of the tested antimicrobials is good, and all antimicrobials showed a WT distribution. Of the tested fluoroquinolones levofloxacin showed the best MDcorr. All macrolides showed a wide MIC distribution and good MDcorr. The MDcorr for cefotaxim, doxycycline and tigecycline was good, while for rifampicin and moxifloxacin, they were not. Conclusion: Overall good correlation between MIC value and disk inhibition zone were found for the fluoroquinolones, macrolides and cefotaxim. (C) 2013 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据