4.3 Article Proceedings Paper

Heat transfer performance and bundle-depth effect in horizontal-tube falling film evaporators

期刊

DESALINATION AND WATER TREATMENT
卷 51, 期 4-6, 页码 830-836

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/19443994.2012.699349

关键词

Horizontal-tube falling film evaporator; Heat transfer coefficient; Bundle-depth effect; Space distribution; Seawater desalination

向作者/读者索取更多资源

A set of experimental facilities were set up to measure overall heat transfer coefficient of horizontal-tube falling film evaporator with square-pitch bundle. Effect of spray density, saturation temperature, total temperature difference, and inlet steam velocity on the overall heat transfer coefficient K is studied. The tubes are made of HAL77-2A aluminum brass with an outer diameter of 25.4 mm. Fluids inside and outside the tubes are steam and fresh water respectively. The results indicate that growth of spray density and saturation temperature helps to increase the K. The K could also be increased by reducing the total temperature difference. However, the impact of the inlet steam velocity on the K is less significant. Furthermore tube bundle-depth effect and space distribution of local overall heat transfer coefficient (K) over tilde in the evaporator are also presented. Based on this investigation, basic engineering design information will be provided to establish the governing parameters for horizontal-tube falling film evaporator in the field of seawater desalination.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据