4.3 Article

Increase of COP for an experimental heat transformer using a water purification system

期刊

DESALINATION AND WATER TREATMENT
卷 12, 期 1-3, 页码 305-312

出版社

DESALINATION PUBL
DOI: 10.5004/dwt.2009.955

关键词

Energy saving; Water purification; Heat transformer; Efficiency of energy use; Desalination

向作者/读者索取更多资源

The experimental results of a water purification system of single effect evaporation integrated into a heat transformer of 700W are presented, using lithium bromide water as solution. It is demonstrated that it is possible to increase efficiency of energy use with heat recycling of a water purification system. The typical coefficients of performance values were increased from 24.7% to 30.3%, obtaining a maximum of 684 mL/h of distilled water. The behavior of the coefficient of performance in function of the absorber temperatures before and after the purification process is showed. Experimental and simulated data with the water purification system integrated into a heat transformer are analyzed.