期刊
DESALINATION
卷 344, 期 -, 页码 383-390出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.desal.2014.04.005
关键词
Evaporation; Condensation; Water depth; Wind velocity; Parameters
This work presents a few important factors that affect the performance of a triangular pyramid solar still. An experimental work has been conducted to find the effect of water depth on the performance of the triangular pyramid solar still. From the present study, it is concluded that the convective and evaporative heat transfer coefficients are important for designing solar distillation systems and the effect of temperature difference between the evaporative and condensing surfaces is also important to optimize the operating temperature range. The condensing area of the solar still is more than that of evaporating area. Thus the experimental results showed that the effect of depth of water in the solar still affects the fresh water production. Nevertheless, outdoor experimental tests were conducted to study the effect of wind speed variations to cool down the glass cover. It was found that increasing the wind speed from 1.5 to 3 m/s and to 4.5 m/s has the effect of increasing the still productivity by Sand 15.5% respectively. (C) 2014 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐