Volatile organic compound removal by membrane gas stripping using electro-spun nanofiber membrane

期刊

DESALINATION
卷 287, 期 -, 页码 98-102

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.desal.2011.04.074

关键词

Water treatment; Volatile organic compound; Membrane air striping; Nanofiber membrane

资金

  1. Ontario Ministry of the Environment (MOE) [78528]

向作者/读者索取更多资源

Removal of volatile organic compound (chloroform) from water was carried out by membrane gas stripping using electro-spun poly(vinylidene fluoride) (PVDF) nanofiber membrane. It was shown that the process was feasible. The overall mass transfer coefficient of chloroform through the nanofiber membrane was found to be 2 x 10(-5) m/s at room temperature, which was more than the highest value obtained earlier for a hollow fiber air-stripping system. The activation energy of the mass transfer coefficient was almost the same as that of the Henry constant for chloroform absorption in water. It was therefore concluded that the chloroform desorption from water was the governing factor of the system. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.