4.7 Article Proceedings Paper

RO membrane autopsy of Zarzis brackish water desalination plant

期刊

DESALINATION
卷 220, 期 1-3, 页码 258-266

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.desal.2007.02.040

关键词

reverse osmosis membrane; antiscaling; desalination plant; fouling; autopsy

向作者/读者索取更多资源

Tunisia, located in a semi-arid zone, has limited water resources. The shortage of good water quality in particular at the south regions required a brackish water desalination to supply these regions with potable water. Zarzis desalination plant, working since 1999, has revealed difficulties related to the loss of membrane performances. In the aim to determine the reason of membrane fouling, foulant layer were analysed. The membrane autopsy has achieved by different methods, such as TOC (total organic carbon) measurement, SEM (scanning electron microscopy), AFM (atomic force microscopy), FTIR (fourier transform infrared spectroscopy) analysis, diffraction by X-ray. Results show that the foulant layer composed mostly of SiO2, clay, organic matter (polysaccharide, protein), CaSiO3, FeO4, AlPO4, and CaSO4. The characteristics bonds obtained by I R indicate the presence of polysaccharides and proteins that constitute a source for further microbiological growth; this is the problem of biofouling. The metallic elements results of corroded stainless steel and internal coating of cartridges filter that are damaged by the silica particle rejected by sand filters. The scale of CaSO4 and CaSiO3 deposition is owing to the bad antiscaling efficiency. The results are presented and discussed in the light of new trends in material.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据