4.6 Article

Freeze-dried acellular dermal matrix graft: Effects of rehydration on physical, chemical, and mechanical properties

期刊

DENTAL MATERIALS
卷 25, 期 9, 页码 1109-1115

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.dental.2009.03.007

关键词

Collagen; Scaffold; Rehydration; Graft; Tensile strength; AlloDerm

向作者/读者索取更多资源

Objectives. To test the effect of rehydration time over the range prescribed in the manufacturer's protocol on (1) the biomechanical properties and on (2) the recovery and stabilization of the collagenous matrix of AlloDerm (R). Methods. A sterile dish containing warm saline solution was prepared, and samples rehydrated for 5 min. Subsequently, three other dishes with the solution were prepared and samples assigned into three groups according to the total rehydration time: 10 min (G1), 20 min (G2), and 40 min (G3). Uni-axial tensile testing was used to assess the biomechanical properties of the different groups and the control (dry condition). Physico-chemical properties were examined by Fourier transform infrared spectroscopy (FT-IR), and differential scanning calorimetry (DSC) as a function of rehydration time. Results. ANOVA revealed a significant change in tensile strength (p = 0.0269) and in elastic modulus (p = 0.0306) for AlloDerm. following different rehydration times. The lowest tensile strength was in the dry condition, whereas the highest was achieved after a 40 min rehydration. The shortest rehydration periods did not result in a statistically significant (p > 0.05) change in elastic modulus. However, after 40 min the elastic modulus increased significantly when compared to the shortest periods. FT-IR confirmed the protein backbone recovery of the graft matrix after rehydration. DSC scans of rehydrated samples showed visible shifts in the denaturation temperature to higher values compared to as-received sample (dry) suggesting stronger polymer-water bridge formation, supporting the increase in the biomechanical properties. Significance. The current study suggests that there are major changes on the biomechanical properties of the collagenous graft as rehydration time increases, which were also structurally confirmed by the physico-chemical analyses. Clinicians must be aware that the rehydration times of the manufacturer's protocol result in a significant range in mechanical and physico-chemical properties. Therefore, a rehydration time of at least 20 min guarantees not only better handling and mechanical properties but, most importantly, supplies a material that closely resembles the natural tissue. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据