4.6 Article

Cure width potential for MOD resin composite molar restorations

期刊

DENTAL MATERIALS
卷 24, 期 8, 页码 1083-1094

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.dental.2008.01.001

关键词

resin composite; light dispersion; emission spectra; photoinitiator; width of cure

向作者/读者索取更多资源

Objectives. To investigate the capability of modern light-curing units exhibiting differences in emission spectra and light source exit window dimensions, for one-shot full-width curing of extensive (molar MOD) resin composite restorations. Method. Specimens of Tetric (TT), Tetric Ceram HB (TC), Tetric Evoceram (TE) and Tetric Ceram Bleach (TB) resin composites containing varying ratios of Lucirin (TPO) and/or camphorquinone (CQ) photoinitiators were packed into a bar-shaped mould (12 mm length x 2 mm width x 2 mm thickness). Each product was irradiated using a halogen (Optilux 401; QTH), a conventional LED (LEDemetron; LED) and two so-called third generation oval-footprint LED light-curing units (LCUs) of the same model. The latter featured bimodal emission spectra (blue and ultraviolet diodes) with either high (unmodified output) and approximately 50% (modified output) blue light intensity (UltraLume-5; ULs, ULm, respectively). Vickers hardness number was obtained across the lateral extent of the bar at 1 mm increments from the centre point on both upper and lower surfaces of the specimens. Results. Significant linear relationships (R-2 = 0.71-0.98) for each distance from the central position of all LCUs were identified between measured light intensity and corresponding upper and lower surface hardness values for each product (P < 0.05). No significant differences (P > 0.05) were recorded in total upper surface hardness of TC or TE cured with LED (68.7 +/- 3.2 and 70.5 +/- 2.5) or ULm (56.8 +/- 2.0 and 57.7 +/- 2.0). However, upper surface hardness of TT (CQ only) cured with ULm was significantly decreased (P < 0.05) compared with other LCUs. When the ratio of hardness at the edge to central positions of the bar-shaped specimens for either surface was calculated, no significant difference (P > 0.05) was identified for TB (containing TPO and decreased CQ) cured with either ULs or ULm (P > 0.05) and was significantly increased (P < 0.05) when cured with ULs compared with LED and QTH. Significance. Variability in light intensity across the curing-tip face, spectral output of dental light-curing units and differences in product photoinitiator chemistry all influence curing efficiency significantly across the width of extensive resin composite geometries. (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据