4.3 Article

Safety and tolerability of brimonidine purite 0.1% and brimonidine purite 0.15%: a meta-analysis of two phase 3 studies

期刊

CURRENT MEDICAL RESEARCH AND OPINION
卷 25, 期 7, 页码 1615-1620

出版社

LIBRAPHARM/INFORMA HEALTHCARE
DOI: 10.1185/03007990902997655

关键词

Alpha-adrenergic agonist; Brimonidine; Glaucoma; Intraocular pressure; Ocular hypertension

向作者/读者索取更多资源

Objective: To compare the safety and tolerability of two formulations of brimonidine ophthalmic solution, brimonidine Purite* (P) 0.1% and brimonidine P 0.15%, for reducing intraocular pressure in patients with glaucoma or ocular hypertension (OHT). Study design and methods: Meta-analysis of safety and tolerability results from two previously reported prospective, randomized, 12-month, double-masked, multi-center, parallel-group clinical studies with similar entry criteria and protocols. In study 1 (two clinical trials), after washout of previous medications, patients with glaucoma or OHT were randomized to thrice-daily treatment with brimonidine P 0.15% (n = 381), brimonidine P = 0.2% (n = 383), or brimonidine 0.2% (n = 383). In study 2 (one clinical trial), the treatment arms were thrice-daily brimonidine P 0.1% (n = 215) and brimonidine 0.2% (n = 218). Main outcome measure: Treatment-related adverse events (AEs) and discontinuations due to AEs. Results: Treatment-related AEs were significantly reduced with brimonidine P 0.15% compared with brimonidine 0.2% in study 1 (p<0.001). Treatment-related AEs and discontinuations due to AEs were significantly reduced with brimonidine P 0.1% compared with brimonidine 0.2% in study 2 (p <= 0.014). In the meta-analysis of study 1 and study 2, the overall incidence of treatment-related AEs was lower with brimonidine P 0.1% than with brimonidine P 0.15% (41.4 vs. 49.7%; p p=0.050). Although the incidence of treatment-related ocular AEs was similar with brimonidine P 0.1% and 0.15% (p=0.461), treatment-related systemic AEs were less frequent with brimonidine P 0.1% than with brimonidine P 0.15% (4.7 vs. 14.2%; p<0.001), and there were fewer discontinuations due to systemic AEs with brimonidine P 0.1% than with brimonidine P 0.15% (p=0.025). Conclusions: Brimonidine P 0.1% has improved systemic safety and tolerability compared with brimonidine P 0.15%. The ocular safety and tolerability of the formulations are similar. The present meta-analysis is based on only two clinical studies, and additional studies further evaluating the safety and tolerability of these medications are warranted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据