期刊
CRYOGENICS
卷 51, 期 6, 页码 347-352出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.cryogenics.2010.12.008
关键词
Magnetic refrigeration; Regenerator; Porous media; Simulation; Cooling capacity
Considering the unignorable factors in practice, a new time independent, 2-dimensional porous media model of room-temperature Active Magnetic Regenerative Refrigeration (AMRR) has been proposed. The 2-D model improved the existing 1-dimensional model by introducing the influence of heat transfer effect though the regenerator wall and conduction for y-axis inside the regenerator. This study compared the previous 1-D model with the 2-D model and concluded that the system can lose 22% of cooling capacity caused by air convection and the conduction loss in y can reach to 10% of cooling capacity. It is concluded that the new model will be useful to predict the performance of room AMRR for more practical conditions. (C) 2010 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐