4.6 Article

Randomized Controlled Trial of Inhaled Nitric Oxide for the Treatment of Microcirculatory Dysfunction in Patients With Sepsis

期刊

CRITICAL CARE MEDICINE
卷 42, 期 12, 页码 2482-2492

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0000000000000549

关键词

clinical trial; inhaled nitric oxide; microcirculation; nitric oxide; resuscitation; sepsis; septic shock; severe sepsis

资金

  1. National Institutes of Health (NIH) (National Institute of General Medical Sciences) [K23GM083211]
  2. NIH
  3. National Institute of Neurological Disorders and Stroke K08
  4. Salem Foundation

向作者/读者索取更多资源

Objectives: Sepsis treatment guidelines recommend macrocirculatory hemodynamic optimization; however, microcirculatory dysfunction is integral to sepsis pathogenesis. We aimed to test the hypothesis that following macrocirculatory optimization, inhaled nitric oxide would improve microcirculation in patients with sepsis and that improved microcirculation would improve lactate clearance and multiple organ dysfunction. Design: Randomized, sham-controlled clinical trial. Setting: Single urban academic medical center. Patients: Adult patients with severe sepsis and systolic blood pressure less than 90 mm Hg despite intravascular volume expansion and/or serum lactate greater than or equal to 4.0 mmol/L. Interventions: After achievement of macrocirculatory resuscitation goals, we randomized patients to 6 hours of inhaled nitric oxide (40 ppm) or sham inhaled nitric oxide administration. We administered study drug via a specialized delivery device that concealed treatment allocation so that investigators and clinical staff remained blinded. Measurements and Main Results: We performed sidestream dark-field videomicroscopy of the sublingual microcirculation prior to and 2 hours after study drug initiation. The primary outcome measure was the change in microcirculatory flow index. Secondary outcomes were lactate clearance and change in Sequential Organ Failure Assessment score. We enrolled 50 patients (28 of 50 [56%] requiring vasopressor agents; 15 of 50 [30%] died). Although inhaled nitric oxide significantly raised plasma nitrite levels, it did not improve microcirculatory flow, lactate clearance, or organ dysfunction. In contrast to previous studies conducted during the earliest phase of resuscitation, we found no association between changes in microcirculatory flow and lactate clearance or organ dysfunction. Conclusions: Following macrocirculatory optimization, inhaled nitric oxide at 40 ppm did not augment microcirculatory perfusion in patients with sepsis. Further, we found no association between microcirculatory perfusion and multiple organ dysfunction after initial resuscitation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据