4.6 Article

Transfer of multidrug-resistant bacteria to healthcare workers' gloves and gowns after patient contact increases with environmental contamination

期刊

CRITICAL CARE MEDICINE
卷 40, 期 4, 页码 1045-1051

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0b013e31823bc7c8

关键词

Acinetobacter; contact precautions; contamination; environment; MRSA; VRE

资金

  1. Merck Pharmaceuticals
  2. AHRQ [1 K08 HS18111-01]
  3. National Institutes of Health [5K24AI079040-02]
  4. VA HSRD Merit IIR [05-123]
  5. Merck
  6. Pfizer
  7. AHRQ [5K08HS018111-03, 541501] Funding Source: Federal RePORTER

向作者/读者索取更多资源

Objective: To assess the role of environmental contamination in the transmission of multidrug-resistant bacteria to healthcare workers' clothing. Design: Prospective cohort. Setting: Six intensive care units at a tertiary care hospital. Subjects: Healthcare workers including registered nurses, patient care technicians, respiratory therapists, occupational/physical therapists, and physicians. Interventions: None. Measurements and Main Results: One hundred twenty of 585 (20.5%) healthcare worker/patient interactions resulted in contamination of healthcare workers' gloves or gowns. Multidrug-resistant Acinetobacter baumannii contamination occurred most frequently, 55 of 167 observations (32.9%; 95% confidence interval [CI] 25.8% to 40.0%), followed by multidrug-resistant Pseudomonas aeruginosa, 15 of 86 (17.4%; 95% CI 9.4% to 25.4%), vancomycin-resistant Enterococcus, 25 of 180 (13.9%, 95% CI 8.9, 18.9%) and methicillin-resistant Staphylococcus aureus, 21 of 152 (13.8%; 95% CI 8.3% to 19.2%). Independent risk factors associated with healthcare worker contamination with multidrug-resistant bacteria were positive environmental cultures (odds ratio [OR] 4.2; 95% CI 2.7-6.5), duration in room for >5 mins (OR 2.0; 95% CI 1.2-3.4), performing physical examinations (OR 1.7; 95% CI 1.1-2.8), and contact with the ventilator (OR 1.8; 95% CI, 1.1-2.8). Pulsed field gel electrophoresis determined that 91% of healthcare worker isolates were related to an environmental or patient isolate. Conclusions: The contamination of healthcare workers' protective clothing during routine care of patients with multidrug-resistant organisms is most frequent with A. baumannii. Environmental contamination was the major determinant of transmission to healthcare workers' gloves or gowns. Compliance with contact precautions and more aggressive environmental cleaning may decrease transmission. (Crit Care Med 2012; 40:1045-1051)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据