4.6 Article

A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: A multi-center, controlled, randomized trial

期刊

CRITICAL CARE MEDICINE
卷 39, 期 4, 页码 613-620

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0b013e318206b5a2

关键词

antimicrobial; antithrombotic; lock solution; hemodialysis; bloodstream infection; catheters; central venous catheter

资金

  1. National Institute of Diabetes and Digestive and Kidney Diseases [5 R44 DK071369-03]
  2. Indiana 21st Century Research and Technology Fund
  3. Oscar Rennebohm Foundation of Madison, WI
  4. National Institutes of Health
  5. Ash Access Technology

向作者/读者索取更多资源

Background and Purpose: Catheter-related bloodstream infection is the greatest threat to the safety of patients on hemodialysis. Catheter lock solutions containing heparin have been linked to an increased risk of hemorrhage and thrombocytopenia. Objectives: To ascertain the safety and efficacy for prevention of catheter-related bloodstream infection and catheter loss from patency failure of a novel catheter lock solution with antimicrobial and antithrombotic activity containing 0.24 M (7.0%) sodium citrate, 0.15% methylene blue, 0.15% methylparaben, and 0.015% propylparaben (C-MB-P), compared with heparin. Design: Multicenter, prospective, randomized, open-label trial with patients studied for up to 6 months. An independent clinical evaluation committee assessing trial outcomes was blinded to patients' treatment assignments. Setting: Twenty-five outpatient hemodialysis units. Patients: Patients with end-stage renal disease receiving maintenance hemodialysis through a percutaneous cuffed and tunneled internal jugular hemodialysis catheters. Interventions: Participants' catheters were locked between hemodialysis sessions with the C-MB-P lock solution or sterile saline containing 5000 units of unfractionated heparin (control). Measurements and Main Results: We recorded and evaluated catheter-related bloodstream infections, catheter loss attributable to luminal thrombosis, and adverse events. A total of 407 patients participated in the trial (49,565 catheter days), 201 in the C-MB-P group and 206 in the heparin group. Patients in the two lock solution groups were comparable for risk factors predisposing to catheter-related bloodstream infection. Catheters locked with C-MB-P were significantly less likely to cause catheter-related bloodstream infection (0.24 vs. 0.82 per 1000 catheter days; relative risk, 0.29; 95% confidence interval, 0.12-0.70; p = .005) and were less likely to be lost because of patency failure (0 vs. 4; log rank, p = .04). Conclusions: The novel C-MB-P lock solution is well tolerated, significantly reduces the risk of catheter-related bloodstream infection, and provides protection comparable to heparin against patency failure. (Crit Care Med 2011; 39:613-620)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据