4.6 Article

Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality

期刊

CRITICAL CARE MEDICINE
卷 39, 期 2, 页码 259-265

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0b013e3181feeb15

关键词

sepsis; septic shock; fluid resuscitation

资金

  1. Canadian Institutes of Health Research

向作者/读者索取更多资源

Objective: To determine whether central venous pressure and fluid balance after resuscitation for septic shock are associated with mortality. Design: We conducted a retrospective review of the use of intravenous fluids during the first 4 days of care. Setting: Multicenter randomized controlled trial. Patients: The Vasopressin in Septic Shock Trial (VASST) study enrolled 778 patients who had septic shock and who were receiving a minimum of 5 mu g of norepinephrine per minute. Interventions: None. Measurements and Main Results: Based on net fluid balance, we determined whether one's fluid balance quartile was correlated with 28-day mortality. We also analyzed whether fluid balance was predictive of central venous pressure and furthermore whether a guideline-recommended central venous pressure of 8-12 mm Hg yielded a mortality advantage. At enrollment, which occurred on average 12 hrs after presentation, the average fluid balance was +4.2 L. By day 4, the cumulative average fluid balance was +11 L. After correcting for age and Acute Physiology and Chronic Health Evaluation II score, a more positive fluid balance at both at 12 hrs and day 4 correlated significantly with increased mortality. Central venous pressure was correlated with fluid balance at 12 hrs, whereas on days 1-4, there was no significant correlation. At 12 hrs, patients with central venous pressure <8 mm Hg had the lowest mortality rate followed by those with central venous pressure 8-12 mm Hg. The highest mortality rate was observed in those with central venous pressure >12 mm Hg. Contrary to the overall effect, patients whose central venous pressure was <8 mm Hg had improved survival with a more positive fluid balance. Conclusions: A more positive fluid balance both early in resuscitation and cumulatively over 4 days is associated with an increased risk of mortality in septic shock. Central venous pressure may be used to gauge fluid balance <= 12 hrs into septic shock but becomes an unreliable marker of fluid balance thereafter. Optimal survival in the VASST study occurred with a positive fluid balance of approximately 3 L at 12 hrs. (Crit Care Med 2011; 39: 259-265)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据