期刊
CORROSION SCIENCE
卷 50, 期 10, 页码 2739-2746出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2008.07.017
关键词
Concrete; Steel reinforced concrete; Galvanostatic; Polarisation; Modelling studies
Uncertainty of the polarised area of reinforcing steel is one of the major sources of error when measuring corrosion rate of steel in concrete. To overcome this problem, instruments equipped with the guard ring, aimed at limiting the polarised area, have been introduced and are available commercially. However, some limitations and disadvantages of the guard ring equipment have been reported [1-5]. In addition, there are some doubts about the appropriate function of such instruments. In this paper, the function of the GalvaPulse (TM), one of the commercially developed equipment using guard ring, is analysed by using the Finite Element Analysis (FEA) technique and the results are compared with results obtained from the laboratory measurements. (c) 2008 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐