期刊
CORROSION
卷 66, 期 5, 页码 -出版社
NATL ASSOC CORROSION ENG
DOI: 10.5006/1.3430465
关键词
corrosion; non-metallic contact; rate measurement
资金
- Ministry of Science and Innovation
- CSIC
All the current techniques used to measure the metallic corrosion require contact with the metal. Particularly, in the case of reinforcement corrosion, this signifies the need to reach the bar that is embedded in the concrete, which consequently may result in the disruption of the integrity of the real structures. This paper studies the limits of application of a new method for polarizing the reinforcement or any metal in an electrolyte, without the need of direct contact. The polarization is obtained through the induction of current from an external electrical. field. The current runs through the electrolyte and the metal in parallel, depending on the electrode arrangement. The resulting polarization resistance calculated is termed as inductive. R-p = R-pi as reported in a previous paper. The inductive R is calculated by the model of resistances in parallel, which requires a separate measurement of the electrolyte ohmic resistance. In this study. solutions with several resistivities and concrete specimens with and without chlorides have been tested. Results indicate that electrolytes of low resistivity mask the measurement, and consequently, R-pi could not be calculated. In electrolytes with high resistivity, such as concrete, the feasibility is found to depend on the relative values of R-e and R-pi.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐