期刊
COORDINATION CHEMISTRY REVIEWS
卷 253, 期 1-2, 页码 56-77出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.ccr.2007.12.001
关键词
Ga(III) octahedral complexes; X-ray crystal structures; Mononuclear Ga(III) complexes; Ga in PET imaging; Ga-based therapeutic agents
Given the commercial availability of Ge-68-Ga-68 generators, in principle analogous to the worldwide utilized Mo-99-Tc-99m generator, it is surprising that few Ga-68 agents have been developed beyond basic research toward clinical application. The use of the unconventional Ga-68 positron emitter would allow for a cost-effective production of Ga-68 radiotracers far from a cyclotron facility. Moreover, the use of Ga-67 radiopharmaceuticals for imaging studies, and the application of non-radioactive gallium compounds in the treatment of important disorders, including a number of cancer and infectious diseases, make studies on trivalent Ga coordination chemistry attractive for the design of novel gallium-based drugs. The aim of this review is to survey the reported crystal data of six-coordinated Ga(III) complexes in order to gain information to be used in the design of novel Ga complexes of medicinal interest. (C) 2007 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐