期刊
CONSTRUCTION AND BUILDING MATERIALS
卷 43, 期 -, 页码 418-427出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2013.02.015
关键词
Unreinforced masonry; In-plane; Shear; Diagonal testing; In situ testing
资金
- New Zealand Foundation for Research, Science and Technology (FRST)
An experimental program was implemented where wall panels were obtained from two existing vintage unreinforced clay brick masonry (URM) buildings and subjected to a diagonal compression loading condition in order to induce a diagonal tension failure mode. The principal aims of the experimental program were to establish the diagonal tension strength of the vintage clay brick URM walls present in the two buildings and to establish a benchmark mortar mix suitable for use when manufacturing replica clay brick test assemblages that adequately represent the strength characteristics present in vintage URM buildings. It was concluded that the use of recycled clay bricks acquired from vintage URM buildings and a mortar mix of 1:2:9 (cement:lime:sand) appropriately replicates the material strength characteristics that are present in existing vintage clay brick URM buildings located in New Zealand. (C) 2013 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐