Effect of fiber type and content on bleeding of steel fiber reinforced concrete

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 25, 期 2, 页码 766-772

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2010.07.008

关键词

Steel fiber; Fiber length; Fiber content; Bleeding; Concrete

向作者/读者索取更多资源

In general, the addition of fibers in concrete mix significantly improves many of the engineering properties of concrete. On the other hand, steel fibers reduce the workability of concrete. This paper presents the effect of steel-fiber length (aspect ratio) and content on bleeding of steel fiber reinforced concrete (SFRC). Two different steel fiber types (both is hooked-end) were used at a ratio of 0% (control), 0.3%, 0.64%, 1% and 1.3% by volume. Slump, Ve-Be test, air content and unit weight were determined experimentally. Specimens were poured in the standard moulds and the bleeding water content was measured 30 min, 60 min, 90 min, 120 min, 150 min and 180 min after starting the test. The results indicated that the workability of concrete significantly reduced as the fiber dosage rate increases. This was assessed through standard slump test and ye-Be consistometer test. The bleeding water content was increased by increase of the fiber volume fraction and fiber aspect ratio according to experimental results. Also, a bleeding coefficient value for SFRC made with and without steel fiber was proposed as a result of this study. (C) 2010 Elsevier Ltd. All rights reserved.