4.7 Article Proceedings Paper

AE monitoring of corrosion process in cyclic wet-dry test

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 24, 期 12, 页码 2353-2357

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2010.05.006

关键词

Acoustic emission; Corrosion of rebar; Reinforced concrete; AE parameter analysis; SiGMA analysis

向作者/读者索取更多资源

Recently, a number of deterioration of reinforced concrete (RC) structures due to salt attack have been reported. After corrosion of reinforcing steel-bar (rebar) is nucleated, expansion of corrosion products results in corrosion-induced cracks in RC. Thus, development of non-destructive evaluation (NDE) techniques is important for inspection of corrosion damage. It is reported that acoustic emission (AE) could identify the onset of corrosion in rebar and the nucleation of concrete cracking due to expansion of corrosion products in the corrosion process. In this study, AE techniques are applied to a cyclic wet dry test of RC beams. It is confirmed that both the onset of corrosion and the nucleation of concrete cracking are clearly observed as two periods of high AE activity. Kinematics of micro-cracks are identified by SiGMA (Simplified Green's functions for moment tensor analysis) analysis of AE. To compare with findings, cross-sections of rebars are observed by SEM (Scanning Electron Micrograph). From these results, a great promise for AE techniques to monitor the corrosion process in RC structures is clarified. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据