4.7 Article

Combined loading of a bridge deck reinforced with a structural FRP stay-in-place form

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 23, 期 4, 页码 1605-1619

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2007.11.008

关键词

Fiber-reinforced-polymer; Stay-in-place form; Military bridge; Shear; Flexural-shear; Combined loading; Neutral axis

资金

  1. University of Wisconsin-Madison in the Wisconsin Structures and Materials Testing Laboratory

向作者/读者索取更多资源

The investigation of a structural fiber-reinforced-polymer (FRP) stay-in-place (SIP) form used to construct and reinforce a deck for a prototype military bridge system is discussed in this paper. For this application the deck is subjected to combined bending and compressive longitudinal axial load because it also serves as the top chord of the truss for the bridge system. In all experimental program, deck specimens were tested in several configurations. The results are compared to ACI 440 design guide equations, and capacity prediction techniques are proposed for limit states associated with flexural and flexural-shear under the combined loading. It was found that the ACI 440 equations accurately predicted the flexural and flexural-shear capacities under combined loads provided that eccentricity due to the combined loading was accounted for in the calculations. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据