4.7 Article

Automatic moment segmentation and peak detection analysis of heart sound pattern via short-time modified Hilbert transform

期刊

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
卷 114, 期 3, 页码 219-230

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.cmpb.2014.02.004

关键词

HS; HS moment segmentation; Peak location; E-T; STMHT; W-E

资金

  1. Grants-in-Aid for Scientific Research [24560261] Funding Source: KAKEN

向作者/读者索取更多资源

This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (E-T) of the HS signal is obtained with an emphasis on the first heart sound (Si) and the second heart sound (S2). Then, based on the characteristics of the E-T and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of E-T can be expressed by multiplying the E-T by an equivalent window (W-E). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N = 1 s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of Si (AP(1)), the peak of S2 (AP(2)), the moment segmentation points from Si to S2 (AT(12)) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where Si cannot be separated from S2, the average accuracies achieved for the peak of Si and S2 (AP(12)) and the cardiac cycle ACC are 100% and 96.69%. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据