3.9 Article

Measuring the positional accuracy of computer assisted surgical tracking systems

期刊

COMPUTER AIDED SURGERY
卷 15, 期 1-3, 页码 13-18

出版社

INFORMA HEALTHCARE
DOI: 10.3109/10929081003775774

关键词

Accuracy; computer assisted surgery; optical tracking; registration

类别

-

向作者/读者索取更多资源

Computer Assisted Orthopaedic Surgery (CAOS) technology is constantly evolving with support from a growing number of clinical trials. In contrast, reports of technical accuracy are scarce, with there being no recognized guidelines for independent measurement of the basic static performance of computer assisted systems. To address this problem, a group of surgeons, academics and manufacturers involved in the field of CAOS collaborated with the American Society for Testing and Materials (ASTM) International and drafted a set of standards for measuring and reporting the technical performance of such systems. The aims of this study were to use these proposed guidelines in assessing the positional accuracy of both a commercially available and a novel tracking system. A standardized measurement object model based on the ASTM guidelines was designed and manufactured to provide an array of points in space. Both the Polaris camera with associated active infrared trackers and a novel system that used a small visible-light camera (MicronTracker) were evaluated by measuring distances and single point repeatability. For single point registration the measurements were obtained both manually and with the pointer rigidly clamped to eliminate human movement artifact. The novel system produced unacceptably large distance errors and was not evaluated beyond this stage. The commercial system was precise and its accuracy was well within the expected range. However, when the pointer was held manually, particularly by a novice user, the results were significantly less precise by a factor of almost ten. The ASTM guidelines offer a simple, standardized method for measuring positional accuracy and could be used to enable independent testing of tracking systems. The novel system demonstrated a high level of inaccuracy that made it inappropriate for clinical testing. The commercially available tracking system performed well within expected limits under optimal conditions, but revealed a surprising loss of accuracy when movement artifacts were introduced. Technical validation of systems may give the user community more confidence in CAOS systems as well as highlighting potential sources of point registration error.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据