4.7 Article Proceedings Paper

Fluid-structure interaction modeling of a patient-specific cerebral aneurysm: influence of structural modeling

期刊

COMPUTATIONAL MECHANICS
卷 43, 期 1, 页码 151-159

出版社

SPRINGER
DOI: 10.1007/s00466-008-0325-8

关键词

fluid-structure interaction; cerebral aneurysm; patient-specific modeling; structural model

向作者/读者索取更多资源

Fluid-structure interaction (FSI) simulations of a cerebral aneurysm with the linearly elastic and hyper-elastic wall constitutive models are carried out to investigate the influence of the wall-structure model on patient-specific FSI simulations. The maximum displacement computed with the hyper-elastic model is 36% smaller compared to the linearly elastic material model, but the displacement patterns such as the site of local maxima are not sensitive to the wall models. The blood near the apex of an aneurysm is likely to be stagnant, which causes very low wall shear stress and is a factor in rupture by degrading the aneurysmal wall. In this study, however, relatively high flow velocities due to the interaction between the blood flow and aneurysmal wall are seen to be independent of the wall model. The present results indicate that both linearly elastic and hyper-elastic models can be useful to investigate aneurysm FSI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据