4.7 Article

Comparative behaviour of hollow columns confined with FRP composites

期刊

COMPOSITE STRUCTURES
卷 93, 期 1, 页码 198-205

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.compstruct.2010.05.020

关键词

Concrete columns; Confinement; Fibre reinforced polymers; High strength concrete; Hollow sections

资金

  1. AusAID (Australian Agency for International Development)

向作者/读者索取更多资源

Confining columns with fibre reinforced polymer (FRP) composites have been investigated in the last few decades to address the problem of upgrading and retrofitting reinforced concrete (RC) columns; however, most studies have concentrated on solid columns. This paper investigates the comparative behaviour of FRP confined hollow RC columns subjected to concentric loading. A total of twelve RC columns made from high strength concrete (HSC) were cast and tested. Six of the columns had a circular cross section (two solid columns, two hollow columns each having a circular hole, and two hollow columns each having a square hole) and the remainder columns had a square cross section (two solid columns, two hollow columns each having a circular hole, and two hollow columns each having a square hole). Six columns in total, three from each configuration were left unconfined as control specimens, while the others were confined with FRP. It was found that FRP confinement increased hollow RC columns' axial load and ductility capacities: and hollow columns having circular holes had better performance compared to hollow columns having square holes. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据