4.4 Article

Comparing the diagnostic values of circulating microRNAs and cardiac troponin T in patients with acute myocardial infarction

期刊

CLINICS
卷 68, 期 1, 页码 75-80

出版社

HOSPITAL CLINICAS, UNIV SAO PAULO
DOI: 10.6061/clinics/2013(01)OA12

关键词

microRNAs; cardiac troponin T; Acute Myocardial Infarction; Circulating Biomarkers

资金

  1. National Natural Science Foundation of China [81071030]
  2. Science and Technology Foundation of Guangdong Province, China [2010B031600089, 2011B080701006]
  3. Training Foundation for the Youth Scholars of Sun Yat-sen University [09ykpy31]

向作者/读者索取更多资源

OBJECTIVE: Recent studies have shown that circulating microRNAs might be useful, novel biomarkers for the diagnosis of acute myocardial infarction. The aims of this study were to evaluate the expression of cardiac-specific miRNAs (miR-1, -133a, -208b, and -499) in patients with acute myocardial infarction and to compare the diagnostic values of these miRNAs with that of cardiac troponin T. METHODS: Sixty-seven plasma samples obtained from patients with acute myocardial infarction and 32 plasma specimens collected from healthy volunteers were analyzed in this study. The levels of cardiac-specific miRNAs (miR-1, -133a, -208b, and -499) were measured by quantitative reverse transcription-polymerase chain reaction, and the concentrations of plasma cardiac troponin T were measured using electrochemiluminescence-based methods and an Elecsys 2010 Immunoassay Analyzer. RESULTS: The levels of plasma miR-1, -133a, -208b, and -499 were significantly higher in acute myocardial infarction patients (all p<0.001) than in healthy volunteers. The expression of the cardiac-specific miRNAs in acute myocardial infarction patients decreased to close to the baseline levels at the time of hospital discharge (all p>0.05). There were no correlations between the levels of the four circulating miRNAs and the clinical characteristics of the study population (all p>0.05). Furthermore, receiver operating characteristic curve analyses showed that the four plasma miRNAs were not superior to cardiac troponin T for the diagnosis of acute myocardial infarction (all p>0.05). CONCLUSION: Our results demonstrate that circulating miR-1, -133a, -208b, and -499 may be useful biomarkers in acute myocardial infarction patients but that these miRNAs are not superior to cardiac troponin T for the diagnosis of acute myocardial infarction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据