Recurrent or persistent infection after two-stage exchange arthroplasty for previously infected total knee replacement is a challenging clinical situation. We asked whether a second two-stage procedure could eradicate the infection and preserve knee function. We evaluated 18 selected patients with failed two-stage total knee arthroplasty implantation treated with a second two-stage reimplantation between 1999 and 2005. Failure of treatment was defined as recurrence or persistence of infection. The minimum followup was 24 months (mean, 40 months; range, 24-83 months). Recurrent or persistent infection was diagnosed in four of 18 patients, two of whom were successfully treated with a third two-stage exchange arthroplasty. Knee Society score questionnaires administered at the last followup showed an average Knee Society knee score of 73 points (range, 24-100 points) and an average functional score of 49 points (range, 20-90 points). The data suggest repeat two-stage exchange arthroplasty is a reasonable option for eradicating periprosthetic infection, relieving pain, and achieving a satisfactory level of function for some patients. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.