ObjectiveTo evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5years of functional loading. Materials and methodsA cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (test group 3). Samples for microbiological analysis were obtained from three types of sites: peri-implant sulci, connections' inside and abutments surface and, as control, gingival sulci of neighboring teeth. Quantitative real-time PCR was carried out for Total Bacterial Count and for 10 microorganisms: Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythensis, Treponema denticola, Prevotella intermedia, Peptostreptococcus micros, Fusobacterium nucleatum, Campylobacter rectus, Eikenella corrodens, and Candida albicans. The response variables were percentage of positive sites and absolute bacterial load. The relations of the response variables with the type of connection and of sampling site were assessed using generalized estimating equations. ResultsRegarding the analysis of positivity to bacteria in the peri-implant sulcus no significant differences were observed. Analyzing the connection's inside, none of the connection designs had the capacity to prevent microbiological leakage through the implant/abutment microgap. Test group 3 presented the lowest mean values for red complex bacteria and control group the highest, although differences were non-significant. Statistical significance was only reached for Treponema denticola in the bacterial load analysis inside the connection. Test groups 1 and 2 yielded lower values for orange complex bacteria but only for Peptostreptococos micros the differences resulted significant. Test groups 2 and 3 had significantly lower total bacterial counts in the peri-implant sulcus and inside the connection. ConclusionsOutcomes suggested that all the analyzed connections resulted contaminated after 5years of functional loading. However, the connection design might influence bacterial activity levels qualitatively and quantitatively, especially inside the implant connection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据