4.5 Article

The effect of maximum bite force on marginal bone loss of mini-implants supporting a mandibular overdenture: a randomized controlled trial

期刊

CLINICAL ORAL IMPLANTS RESEARCH
卷 21, 期 2, 页码 243-249

出版社

WILEY
DOI: 10.1111/j.1600-0501.2009.01834.x

关键词

marginal bone loss; maximum bite force; mini-implants; overdentures

资金

  1. National Commission for Scientific and Technological Research of Chile (CONICYT), through the Fund for the Promotion of Scientific and Technological Development [Di1109]

向作者/读者索取更多资源

Objectives To evaluate the effect of maximum bite force (mBF) on marginal bone loss (MBL) around mini-implants in edentulous patients wearing mandibular overdentures with two retention systems: ball and bar. Material and methods Forty-five totally edentulous patients were selected from a public health center. All of them received two mini-implants (1.8 x 15 mm; Sendax (R)) in the anterior mandible using a minimally invasive technique. A single randomization was performed to allocate the patients in two groups. Group I (n=22) received two single ball-type mini-implants and Group II (n=23) received two mini-implants splinted with a prefabricated bar. The mBF was recorded using a press-sensitive sheet Dental Prescale (R) (Fuji) and MBL using standardized radiographs of each mini-implant at the baseline and 5, 7, 10, and 15 months after surgery; the values were compared between groups. Results Two members of Group I failed to complete the study, decreasing the number of participants to 20. There was no relationship between the mBF and the MBL of the mini-implants (Spearman's r(s)=0.147; P=0.378). At the 15-month follow-up, the average mBF for Group I (ball) was 247.53 +/- 132.91 N and that of Group II (bar) only 203.23 +/- 76.85 N (Mann-Whitney test; P=0.586). The MBL values were also higher for Group I (1.40 +/- 1.02 mm) than Group II (0.84 +/- 0.66 mm) during the entire 15-month follow-up period (Mann-Whitney test; P=0.077). Conclusions No relationship was found between mBF and MBL for patients wearing overdentures retained on mini-implants using bar or ball attachment systems. To cite this article:Jofre J, Hamada T, Nishimura M, Klattenhoff C. The effect of maximum bite force on marginal bone loss of mini-implants supporting a mandibular overdenture: a randomized controlled trial.Clin. Oral Impl. Res. 21, 2010; 243-249.doi: 10.1111/j.1600-0501.2009.01834.x.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据