Effect of Flow Diverter Porosity on Intraaneurysmal Blood Flow

期刊

CLINICAL NEURORADIOLOGY
卷 19, 期 3, 页码 204-214

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00062-009-9005-0

关键词

Intracranial aneurysms; Particle image velocimetry; Porosity; Experimental setup; Shear-driven flow; Inertia-driven flow

资金

  1. Egon Naef Foundation
  2. Swiss National Research Foundation [3252B0-105735/1]
  3. European Commission [IST-027703]

向作者/读者索取更多资源

Background and Purpose: Growth and rupture, the two events that dominate the evolution of an intracranial aneurysm, are both dependent on intraaneurysmal flow. Decrease of intraaneurysmal flow is considered an attractive alternative for treating intracranial aneurysms by minimally invasive techniques. Such modification can be achieved by inserting stents or flow diverters atone. In the present paper, the effect of different commercial and innovative flow diverters' porosity was studied in intracranial aneurysm models. Material and Methods:Single and stent-in-stent combination of Neuroform II as well as single and stent-in-stent combination of a new innovative, low-porosity, intracranial stent device (D1, D2, D1 + D2) were inserted in models of intracranial. aneurysms under shear-driven flow and inertia-driven flow configurations. Steady and pulsating flow rates were applied using a blood-like fluid. Particle image velocimetry was used to measure velocity vector fields in the aneurysm midplane along the vessel axis. Flow and vorticity patterns, velocity and vorticity magnitudes were quantified and their value compared with the same flows in absence of the flow diverter. Results: In absence of flow diverters, a solid-like rotation could be observed in both shear-driven and inertia-driven models under steady and pulsatile flow conditions. The flow effects due to the insertion of low-porous devices such as D1 or D2 provoked a complete alteration of the flow patterns and massive reduction of velocity or vorticity magnitudes, whereas the introduction of clinically adopted high-porous devices provoked Less effect in the aneurysm cavity. As expected, results showed that the tower the porosity the Larger the reduction in velocity and vorticity within the aneurysm cavity. The Lowest-porosity device combination (D1 and D2) reached an averaged reduction of flow parameters of 80% and 88% under steady and pulsatile flow conditions, respectively. The reduction in mean velocity and vorticity was much more significant in the shear-driven flows as compared to the inertia-driven flows. Conclusion: Although device porosity is the main parameter influencing flow reduction, other parameters such as device design and Local flow conditions may influence the Level of Row reduction within intracranial aneurysms.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据