4.6 Article

Intracerebrally recorded high frequency oscillations: Simple visual assessment versus automated detection

期刊

CLINICAL NEUROPHYSIOLOGY
卷 124, 期 10, 页码 1935-1942

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.clinph.2013.03.032

关键词

High frequency oscillations; Spikes; Ripples; Fast ripples; Temporal lobe epilepsy; Extratemporal lobe epilepsy; Seizure onset zone; Epileptogenic zone

资金

  1. CEITEC - Central European Institute of Technology'' project [CZ. 1.05/1.1.00/02.0068]
  2. European Regional Development Fund
  3. MSMT C.R Research Program [MSM0021622404]
  4. GACR [P103/11/0933]
  5. Application Laboratories of Advanced Microtechnologies and Nanotechnologies [CZ. 1.05/2.1.00/01.0017]
  6. Operational Programme Research and Development for Innovations''

向作者/读者索取更多资源

Objective: We compared the possible contribution (in the detection of seizure onset zone -SOZ) of simple visual assessment of intracerebrally recorded high-frequency oscillations (HFO) with standard automated detection. Methods: We analyzed stereo-EEG (SEEG) recordings from 20 patients with medically intractable partial seizures (10 temporal/10 extratemporal). Independently using simple visual assessment and automated detection of HFO, we identified the depth electrode contacts with maximum occurrences of ripples (R) and fast ripples (FR). The SOZ was determined by independent visual identification in standard SEEG recordings, and the congruence of results from visual versus automated HFO detection was compared. Results: Automated detection of HFO correctly identified the SOZ in 14 (R)/10 (FR) out of 20 subjects; a simple visual assessment of SEEG recordings in the appropriate frequency ranges correctly identified the SOZ in 13 (R)/9 (FR) subjects. Conclusions: Simple visual assessment of SEEG traces and standard automated detection of HFO seem to contribute comparably to the identification of the SOZ in patients with focal epilepsies. When using macroelectrodes in neocortical extratemporal epilepsies, the SOZ might be better determined by the ripple range. Significance: Standard automated detection of HFO enables the evaluation of HFO characteristics in whole data. This detection allows general purpose and objective evaluation, without any bias from the neurophysiologist's experiences and practice. (C) 2013 Published by Elsevier Ireland Ltd. on behalf of International Federation of Clinical Neurophysiology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据