4.6 Article

A comparative study of different references for EEG default mode network: The use of the infinity reference

期刊

CLINICAL NEUROPHYSIOLOGY
卷 121, 期 12, 页码 1981-1991

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.clinph.2010.03.056

关键词

EEG reference; Power spectra; Coherence; Connectivity; DMN; Frequency bands

资金

  1. NSFC [60736029, 30525030, 60701015]
  2. 863 Project [2009AA02Z301]

向作者/读者索取更多资源

Objective: The choice of electroencephalograph (EEG) reference is a critical issue for the study of brain activity. The present study addressed the use of the infinity reference obtained by the reference electrode standardisation technique (REST) in the study of EEG default mode network (DMN). Methods: A total of 100 randomly positioned source configurations, each consisting of two dipoles with coherent waveforms, were adopted for simulating EEG networks. Dense (129-channel), eyes-closed EEG was recorded from 15 subjects. Simulated data with infinity as reference and the real data were re-referenced to reconstructed infinity (REST), their average (AR), linked mastoids (LM) and left mastoid (L) references. For simulated data, the effects of different references on coherence and network were investigated. For real data, spectral properties of seven conventional EEG frequency bands were first analysed and then DMN was constructed based on the coherence. Results: The simulation showed that REST can exactly recover the true EEG network configuration. For real EEG data, significant differences among references were found for the power spectra, coherence and DMN configuration. Compared with REST, the long-distance connectivity between anterior and posterior areas was strengthened by AR, and the connectivity over posterior areas was destroyed when LM and L were employed. Moreover, all comparisons demonstrated frequency-dependent reference effects. Conclusions: Non-neutral reference influences the power spectra, coherence as well as the network analysis. REST demonstrates its validity in data referencing, and meanwhile, AR is much closer to REST than the other references in terms of spectra and coherence. However, the DMN alters a great deal with AR. Significance: The results underscore the importance of considering EEG reference effects in the functional connectivity studies. REST is a promising reference technique for objective comparison in cross-laboratory studies and clinical practices. (C) 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据