4.6 Article

Pharmacokinetics and Pharmacodynamics of Piperacillin-Tazobactam in 42 Patients Treated with Concomitant CRRT

出版社

AMER SOC NEPHROLOGY
DOI: 10.2215/CJN.10741011

关键词

-

资金

  1. NxStage Medical
  2. National Institutes of Health [1R21DK088045]
  3. Cleveland Clinic

向作者/读者索取更多资源

Background and objectives Current recommendations for piperacillin-tazobactam dosing in patients receiving continuous renal replacement therapy originate from studies with relatively few patients and lower continuous renal replacement therapy doses than commonly used today. This study measured the pharmacokinetic and pharmacodynamic characteristics of piperacillin-tazobactam in patients treated with continuous renal replacement therapy using contemporary equipment and prescriptions. Design, setting, participants, & measurements A multicenter prospective observational study in the intensive care units of two academic medical centers was performed, enrolling patients with AKI or ESRD receiving piperacillin-tazobactam while being treated with continuous renal replacement therapy. Pregnant women, children, and patients with end stage liver disease were excluded from enrollment. Plasma and continuous renal replacement therapy effluent samples were analyzed for piperacillin and tazobactam levels using HPLC. Pharmacokinetic and pharmacodynamic parameters were calculated using standard equations. Multivariate analyses were used to examine the association of patient and continuous renal replacement therapy characteristics with piperacillin pharmacokinetic parameters. Results Forty-two of fifty-five subjects enrolled had complete sampling. Volume of distribution (median=0.38 L/kg, intraquartile range=0.20 L/kg) and elimination rate constants (median=0.104 h(-1), intraquartile range=0.052 h(-1)) were highly variable, and clinical parameters could explain only a small fraction of the large variability in pharmacokinetic parameters. Probability of target attainment for piperacillin was 83% for total drug but only 77% when the unbound fraction was considered. Conclusions There is significant patient to patient variability in pharmacokinetic/pharmacodynamic parameters in patients receiving continuous renal replacement therapy. Many patients did not achieve pharmacodynamic targets, suggesting that therapeutic drug monitoring might optimize therapy. Clin J Am Soc Nephrol 7: 452-457, 2012. doi: 10.2215/CJN.10741011

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据