期刊
CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY
卷 4, 期 4, 页码 184-187出版社
KOREAN SOC OTORHINOLARYNGOL
DOI: 10.3342/ceo.2011.4.4.184
关键词
Korean version of Sniffin' stick test; T&T olfactometer
资金
- Ministry for Health, Welfare & Family Affairs, Republic of Korea [A090084]
- National Research Foundation of Korea (NRF)
- Ministry of Education, Science, and Technology [2010-0010279]
- National Research Foundation of Korea [2010-0010279] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
Objectives. The Korean version of the Sniffin' stick (KVSS) test is widely used in Korea to evaluate olfactory function. However, its validity and reliability have not been studied well. In this study, the authors administered the KVSS and the T&T olfactometer test to evaluate olfactory function and to establish relationships between these two test measures. Methods. Two hundred and eleven patients participated in this prospective randomized study. One hundred and nine patients with no olfactory symptoms and 102 patients with decreased olfaction participated. All participants were underwent KVSS H and T&T olfactometer testing. Results. The mean recognition threshold of the T&T olfactometer was -1.8 +/- 0.9 for patients with normal olfaction and 4.0 +/- 2.6 for patients with decreased olfaction. The mean Threshold-Discrimination-Identification score of the KVSS H was 30.0 +/- 3.8 for patients with normal olfaction and 15.9 +/- 7.1 for patients with decreased olfaction. Correlation coefficient between the two tests was significantly high (r(s)=-0.725, P<0.01). Conclusion. The KVSS and T&T olfactometry test are both reliable tests of olfactory function and their results are well correlated with each other.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐