4.3 Article

Randomized Comparison of the Nobori Biolimus A9-Eluting Coronary Stent With the Taxus Liberte Paclitaxel-Eluting Coronary Stent in Patients With Stenosis in Native Coronary Arteries The NOBORI 1 Trial - Phase 2

期刊

CIRCULATION-CARDIOVASCULAR INTERVENTIONS
卷 2, 期 3, 页码 188-U57

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCINTERVENTIONS.108.823443

关键词

drug eluting stent; angioplasty; Biolimus A9; paclitaxel; randomized trial

向作者/读者索取更多资源

Background - The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation. Methods and Results - We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberte, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11 +/- 0.30 mm versus 0.32 +/- 0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberte stent (P < 0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5 +/- 7.2% in Taxus to 1.8 +/- 5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm. Conclusions - The NOBORI 1 clinical trial confirmed its primary hypothesis-noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberte stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population. (Circ Cardiovasc Intervent. 2009;2:188-195.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据