4.6 Article

Diagnostic Accuracy and Impact of Computed Tomographic Coronary Angiography on Utilization of Invasive Coronary Angiography

期刊

CIRCULATION-CARDIOVASCULAR IMAGING
卷 2, 期 1, 页码 16-23

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCIMAGING.108.792572

关键词

computed tomography; coronary angiography; clinical impact; accuracy; normalcy

资金

  1. Canadian Institute of Health Research New Investigator [MSH-83718]
  2. Heather and Whit Tucker Research Fellowship in Cardiology

向作者/读者索取更多资源

Background-Computed tomographic coronary angiography (CTA), given its high negative predictive value, is a potential gatekeeper for invasive coronary angiography (ICA). Before CTA can be further accepted into clinical practice, its impact on healthcare resources needs to be better understood. We sought to determine the clinical impact of CTA on ICA referrals, CTA accuracy, and normalcy rate. Methods and Results-To determine the impact of CTA, consecutive patients (n=7017) undergoing ICA before and after implementing a dedicated cardiac CT program were reviewed and compared with 3 other centers (n=11 508). To determine CTA accuracy, we evaluated consecutive CTA patients who underwent ICA. For normalcy rate, we identified patients with a low pretest probability for obstructive coronary artery disease. With the implementation of a cardiac CT program, the frequency of normal ICA decreased from 31.5% (1114 of 3538 patients) to 26.8% (932 of 3479 patients) (P<0.001). These findings were significantly different (P=0.003) from the 3 centers, in which normal ICAs were unchanged (30.0% [1870 of 6224 patients] to 31.0% [1642 of 5284 patients.]). CTA had excellent per-patient sensitivity (99% [CI, 95% to 100%]), positive predictive value (92% [CI, 86% to 96%]) and negative predictive value (95% [CI, 72% to 100%]). Because of referral bias., specificity (64% [CI, 44% to 81%1) was low; however, the normalcy rate of CTA was 94% (CI. 90% to 97%). After adjusting for referral bias, the adjusted sensitivity was 90% (CI, 89% to 9 1 %) and the adjusted specificity was 95% (CI, 94% to 96%), with positive and negative predictive values of 92% (CI, 91% to 93%) and 93% (CI 92% to 94%), respectively. Conclusion-The clinical implementation of CTA appears to positively impact ICA by reducing the frequency of normal ICA. The operating characteristics of CTA support its potential role Lis a tool useful in ruling out obstructive coronary artery disease. (Circ Cardiovasc Imaging. 2009;2:16-23.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据