4.5 Article

Left-to-Right Atrial Inward Rectifier Potassium Current Gradients in Patients With Paroxysmal Versus Chronic Atrial Fibrillation

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.110.954636

关键词

atrium; fibrillation; ion channels; remodeling

资金

  1. Deutsche Forschungsgemeinschaft [Do769/1-1-3]
  2. German Federal Ministry of Education and Research through the Atrial Fibrillation Competence Network [01Gi0204]
  3. Canadian Institutes of Health Research [MOP44365]
  4. Fondation Leducq [07CVD03]

向作者/读者索取更多资源

Background-Recent evidence suggests that atrial fibrillation (AF) is maintained by high-frequency reentrant sources with a left-to-right-dominant frequency gradient, particularly in patients with paroxysmal AF (pAF). Unequal left-to-right distribution of inward rectifier K+ currents has been suggested to underlie this dominant frequency gradient, but this hypothesis has never been tested in humans. Methods and Results-Currents were measured with whole-cell voltage-clamp in cardiomyocytes from right atrial (RA) and left (LA) atrial appendages of patients in sinus rhythm (SR) and patients with AF undergoing cardiac surgery. Western blot was used to quantify protein expression of I-K1 (Kir2.1 and Kir2.3) and I-K,I-ACh (Kir3.1 and Kir3.4) subunits. Basal current was approximate to 2-fold larger in chronic AF (cAF) versus SR patients, without RA-LA differences. In pAF, basal current was approximate to 2-fold larger in LA versus RA, indicating a left-to-right atrial gradient. In both atria, Kir2.1 expression was approximate to 2-fold greater in cAF but comparable in pAF versus SR. Kir2.3 levels were unchanged in cAF and RA-pAF but showed a 51% decrease in LA-pAF. In SR, carbachol-activated (2 mu mol/L) I-K,I-ACh was 70% larger in RA versus LA. This right-to-left atrial gradient was decreased in pAF and cAF caused by reduced I-K,I-ACh in RA only. Similarly, in SR, Kir3.1 and Kir3.4 proteins were greater in RA versus LA and decreased in RA of pAF and cAF. Kir3.1 and Kir3.4 expression was unchanged in LA of pAF and cAF. Conclusions-Our results support the hypothesis that a left-to-right gradient in inward rectifier background current contributes to high-frequency sources in LA that maintain pAF. These findings have potentially important implications for development of atrial-selective therapeutic approaches. (Circ Arrhythm Electrophysiol. 2010;3:472-480.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据