4.8 Article

Clinical Impact of Persistent Left Bundle-Branch Block After Transcatheter Aortic Valve Implantation With CoreValve Revalving System

期刊

CIRCULATION
卷 127, 期 12, 页码 1300-1307

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.112.001099

关键词

aortic valve; bioprosthesis; cardiac pacemaker, artificial; left bundle-branch block; prognosis

向作者/读者索取更多资源

Background-Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation. Methods and Results-Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174-798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation. Conclusions-In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation. (Circulation. 2013; 127: 1300-1307.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据