4.8 Article

Very Late Coronary Stent Thrombosis of a Newer-Generation Everolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents A Prospective Cohort Study

期刊

CIRCULATION
卷 125, 期 9, 页码 1110-U108

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.111.058560

关键词

drug-eluting stents; registries; thrombosis

资金

  1. CTU Bern
  2. Bern University Hospital
  3. Institute of Social and Preventive Medicine
  4. University of Bern
  5. Swiss National Science Foundation [33CM30-124112]
  6. Abbott Vascular
  7. Biosensors
  8. Medtronic
  9. Johnson Johnson
  10. Abbott
  11. Boston Scientific
  12. Cordis

向作者/读者索取更多资源

Background-Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES). Methods and Results-We assessed the risk of stent thrombosis in a cohort of 12 339 patients with unrestricted use of drug-eluting stents (3819 SES, 4308 PES, 4212 EES). Results are incidence rates per 100 person-years after inverse probability of treatment weighting to adjust for group differences. During follow-up of up to 4 years, the overall incidence rate of definite stent thrombosis was lower with EES (1.4 per 100 person-years) compared with SES (2.9; hazard ratio, 0.41; 95% confidence interval, 0.27-0.62; P<0.0001) and PES (4.4; hazard ratio, 0.33; 95% confidence interval, 0.23-0.48; P<0.0001). The incidence rate per 100 person-years of early (0-30 days), late (31 days-1 year), and very late stent thrombosis amounted to 0.6, 0.1, and 0.6 among EES-treated patients; 1.0, 0.3, and 1.6 among SES-treated patients; and 1.3, 0.7, and 2.4 among PES-treated patients. Differences in favor of EES were most pronounced beyond 1 year, with a hazard ratio of 0.33 (EES versus SES; P=0.006) and 0.34 (EES versus PES; P<0.0001). There was a lower risk of cardiac death or myocardial with EES compared with PES (hazard ratio, 0.65; 95% confidence interval, 0.56-0.75; P<0.0001), which was directly related to the lower risk of stent thrombosis-associated events (EES versus PES: hazard ratio, 0.36; 95% confidence interval, 0.23-0.57). Conclusion-Current treatment with EES is associated with a lower risk of very late stent thrombosis compared with early-generation drug-eluting stents. (Circulation. 2012;125:1110-1121.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据