4.8 Article

Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial

期刊

CIRCULATION
卷 124, 期 8, 页码 886-U84

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.110.015453

关键词

coronary artery disease; drug-eluting stent; diabetes mellitus

资金

  1. Cardiovascular Research Foundation (Korea)
  2. Ministry for Health, Welfare and Family Affairs, Republic of Korea [0412-CR02-0704-0001]

向作者/读者索取更多资源

Background-Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus. Methods and Results-This prospective, multicenter, randomized study compared everolimus-eluting stent (n = 149) and sirolimus-eluting stent (n = 151) implantation in diabetic patients. The primary end point was noninferiority of angiographic in-segment late loss at 8 months. Clinical events were also monitored for at least 12 months. Everolimus-eluting stents were noninferior to sirolimus-eluting stents for 8-month in-segment late loss (0.23 +/- 0.27 versus 0.37 +/- 0.52 mm; difference, -0.13 mm; 95% confidence interval, -0.25 to -0.02; upper 1-sided 95% confidence interval, -0.04; P<0.001 for noninferiority), with reductions in in-stent restenosis (0% versus 4.7%; P=0.029) and in-segment restenosis (0.9% versus 6.5%; P=0.035). However, in-stent late loss (0.11 +/- 0.26 versus 0.20 +/- 0.49 mm; P=0.114) was not statistically different between the 2 groups. At 12 months, ischemia-driven target lesion revascularization (0.7% versus 2.6%; P=0.317), death (1.3% versus 3.3%; P=0.448), and myocardial infarction (0% versus 1.3%; P=0.498) were not statistically different between the 2 groups. Major adverse cardiac events, including death, myocardial infarction, and ischemia-driven target lesion revascularization (2.0% versus 5.3%; P=0.218), were also not statistically different between the 2 groups. Conclusions-Everolimus-eluting stents were noninferior to sirolimus-eluting stents in reducing in-segment late loss and reduced angiographic restenosis at 8 months in patients with diabetes mellitus and coronary artery disease.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据