4.8 Article

First Clinical Application of an Actively Reversible Direct Factor IXa Inhibitor as an Anticoagulation Strategy in Patients Undergoing Percutaneous Coronary Intervention

期刊

CIRCULATION
卷 122, 期 6, 页码 614-622

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.109.927756

关键词

angioplasty; anticoagulants; coronary disease; thrombosis

资金

  1. Regado Biosciences Inc.
  2. Eli Lilly/Daiichi-Sankyo Alliance
  3. Archemix Inc
  4. Sanofi-Aventis
  5. Bayer-Japan
  6. Bayer Pharmaceuticals
  7. BMS
  8. Johnson Johnson
  9. Medicines Co
  10. Momenta Pharmaceuticals
  11. Schering-Plough Research Institute

向作者/读者索取更多资源

Background-The ideal anticoagulant should prevent ischemic complications without increasing the risk of bleeding. Controlled anticoagulation is possible with the REG1 system, an RNA aptamer pair comprising the direct factor IXa inhibitor RB006 and its active control agent RB007. Methods and Results-This phase 2a study included a roll-in group (n=2) treated with REG1 plus glycoprotein IIb/IIIa inhibitors followed by 2 groups randomized 5: 1 to REG1 or unfractionated heparin. In group 1 (n=12), RB006 was partially reversed with RB007 after percutaneous coronary intervention and fully reversed 4 hours later. In group 2 (n=12), RB006 was fully reversed with RB007 immediately after percutaneous coronary intervention. Femoral sheaths were removed after complete reversal. Patients were pretreated with aspirin and clopidogrel. End points included major bleeding within 48 hours; composite of death, myocardial infarction, or urgent target vessel revascularization within 14 days; and pharmacodynamic measures. All cases were successful, with final Thrombolysis in Myocardial Infarction grade 3 flow and no angiographic thrombotic complications. There were 2 ischemic end points in the REG1 group and 1 in the unfractionated heparin group, with 1 major bleed in the unfractionated heparin group. Median activated clotting time values rose from 151 to 236 seconds after RB006. Administration of the partial RB007 dose reversed anticoagulation to an intermediate activated clotting time value of 186 seconds. Complete reversal with RB007 returned the median activated clotting time value to 144 seconds. Both reversal strategies enabled scheduled femoral sheath removal. Conclusions-This study demonstrates the clinical translation of a novel platform of anticoagulation targeting factor IXa and its active reversal to percutaneous coronary intervention and provides the basis for further investigation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据