4.5 Article

Influences of Temperature and pH Value on the Corrosion Behaviors of X80 Pipeline Steel in Carbonate/Bicarbonate Buffer Solution

期刊

CHINESE JOURNAL OF CHEMISTRY
卷 26, 期 10, 页码 1799-1805

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/cjoc.200890324

关键词

cyclic voltammetry (CV); electrochemical impedance spectroscopy (EIS); Mott-Schottky analysis; carbonate/bicarbonate buffer solution

向作者/读者索取更多资源

The joint effect of temperature and pH value on the corrosion behavior of X80 steel in carbonate/bicarbonate buffer solution was detected by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Mott-Schottky analysis. The results show that an unstable corrosion film will be formed on the X80 steel surface in low pH value solutions, and a better protective corrosion film can be formed on the X80 steel surface in high pH value solutions. On the whole, the corrosion film resistance and transfer resistance increase with the increment of pH value, and decrease with increase of solution temperature, which indicates that the protective effect of the corrosion film on X80 steel is enhanced with increasing pH value and decreasing the solution temperature. The corrosion film formed on X80 steel surface in carbonate/bicarbonate buffer solution has an n-type semi-conductive character, and the donor density decreases with increasing the pH value, and increases with increasing the solution temperature. The flat-band potential and pH value have a linear relationship with a positive slope.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据