4.5 Article

Turbulent Heat Transfer and Pressure Drop in Tube Fitted with Square-cut Twisted Tape

期刊

CHINESE JOURNAL OF CHEMICAL ENGINEERING
卷 18, 期 4, 页码 609-617

出版社

CHEMICAL INDUSTRY PRESS CO LTD
DOI: 10.1016/S1004-9541(10)60264-9

关键词

heat transfer enhancement; friction factor; plain twisted tape; square-cut twisted tape; secondary flow

向作者/读者索取更多资源

Heat transfer, friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes (STT) and plain twisted tapes (PTT) are investigated experimentally using the water as working fluid. The tapes (STT and PTT) have three twist ratios (y = 2.0, 4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000. The experimental results reveal that heat transfer rate, friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance. Over the range considered, the Nusselt number, friction factor and thermal enhancement factor in a tube with STT are respectively, 1.03 to 1.14, 1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT. An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据