4.6 Article

Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

期刊

CHINESE JOURNAL OF AERONAUTICS
卷 27, 期 3, 页码 643-654

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cja.2014.04.025

关键词

Condition indicators; Health indicator; Helicopter transmission systems; Mann-Kendall test; Physical model; Sensitivity analysis; Sen slop estimator; Sensor selection

资金

  1. National Natural Science Foundation of China [51175502]

向作者/读者索取更多资源

In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs) are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann-Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI) through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitoring of helicopter transmission systems, and it is effective to reduce the test cost and improve the system's reliability. (C) 2014 Production and hosting by Elsevier Ltd. on behalf of CSAA & BUAA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据