期刊
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION
卷 50, 期 9, 页码 952-958出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.cep.2011.07.004
关键词
Calcium carbonate; Antiscale magnetic treatment; Electromagnets
This paper reviews electromagnetic water treatment, an alternative solution for scale control in industrial water processing, and a model device with solenoid coils inserted into a cylindrical kernel inside a pipe is analyzed for potential application at high water-flow capacity (few hundreds of m(3)/h). An efficiently strong magnetic field (e.g. with maximum magnetic flux density from 0.1T to 0.2T) can be produced using a DC electric supply resulting in total costs at least ten times lower than the expense of the scale-prevention ion exchange. (C) 2011 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐