4.7 Article Proceedings Paper

Implementation of laser-induced breakdown spectroscopy as a continuous emissions monitor for toxic metals

期刊

WASTE MANAGEMENT
卷 20, 期 5-6, 页码 455-462

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0956-053X(00)00011-8

关键词

laser-induced breakdown spectroscopy (LIBS); toxic metals; continuous emission monitor

向作者/读者索取更多资源

Laser-induced breakdown spectroscopy (LIBS) has been considered for some time as a potential CEM method for toxic metals. Recently, improvements in sampling methodology and signal processing have allowed LIES to achieve detection limits below the proposed MACT limits for 5 out of 6 of the RCRA metals. This paper discusses performance improved by nearly 2 orders of magnitude of this in situ monitoring technique following implementation of conditional analysis. Results from trial burns at two incinerators and at a DoD contained burn facility are highlighted. At the incinerators, implementation of conditional analysis yielded much lower detection limits than previously reported using the LIBS technique. At the contained burn facility, reproducible, transient Pb measurements were recorded in real-time for concentration values that varied by more than two orders of magnitude. Method detection limits of between 2 and 100 mu g/dscm are reported for toxic metals Be, Cd, Cr, He, and Pb. (C) 2000 Elsevier Science Ltd. All rights reserved.