4.7 Article

Normal tissue dosimetric comparison between HDR prostate implant boost and conformal external beam radiotherapy boost: Potential for dose escalation

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/S0360-3016(99)00501-5

关键词

high-dose-rate brachytherapy; prostate cancer; dosimetry; linear-quadratic equation; critical volume tolerance

向作者/读者索取更多资源

Purpose: To compare the dose and volume of bladder and rectum treated using high-dose-rate (HDR) prostate implant boost versus conformal external beam radiotherapy boost, and to use the dose-volume information to perform a critical volume tolerance (CVT) analysis and then estimate the potential for further dose escalation using HDR brachytherapy boost. Methods and Materials: Using CT scan data collected before and after patients underwent HDR prostate implant, a 7-field conformal prostate-only external beam treatment plan and HDR brachytherapy treatment plan were constructed for each patient. Doses to the normal structures were calculated. Dose-volume histograms (DVH) were plotted for comparison of the two techniques. Wilcoxon signed rank test was performed at four dose levels to compare the dose to normal structures between the two treatment techniques. The acute and late effects of HDR brachytherapy were calculated based on the linear-quadratic (LQ) model. CVT analyses were performed to calculate the potential dose gain (PDG) using HDR brachytherapy boost. Results: The volume of bladder and rectum receiving high dose was significantly less from implant boost. On the average, 0.19 cc of the bladder received 100% of the brachytherapy prescription dose, compared with 5.1 cc of the bladder receiving 100% of the prescription dose in the 7-field conformal external beam radiotherapy boost. Similarly, 0.25 cc of the rectum received 100% of the dose with the implant boost, as compared to 2.9 cc in the conformal external beam treatment. The implant also delivered higher doses inside the prostate volume. On average, 47% of the prostate received greater than or equal to 150% of the prescription dose. The CVT analysis revealed a range of PDG using the HDR brachytherapy boast which depended on the following variables: critical volume (CV), critical volume tolerance dose (CVTD), number of HDR fractions (N), and the dose of external beam radiotherapy (XRT) delivered with brachytherapy boost. The PDG varied from -3.45% to 10.53% for tumor with an alpha-beta ratio of 10 and 7.14% to 64.6% for tumor with an alpha-beta ratio of 1.5 based on the parameters used for calculation in this study. Conclusions: HDR brachytherapy can provide better sparing of rectum and bladder while delivering a higher dose to the prostate. Even with the increased late effects of high dose per fraction, there is still a potential for dose escalation beyond external radiotherapy limits using HDR brachytherapy. (C) 2000 Elsevier Science Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据