4.5 Article

A newly designed tensile tester for cells and its application to fibroblasts

期刊

JOURNAL OF BIOMECHANICS
卷 33, 期 1, 页码 97-104

出版社

ELSEVIER SCI LTD
DOI: 10.1016/S0021-9290(99)00161-X

关键词

tensile test; cell; fibroblast; mechanical property; cellular mechanics

向作者/读者索取更多资源

A tensile test system for cells has been designed and applied to fibroblasts from the rabbit patellar tendon. It consists of a thermostatic test chamber, an inverted fluorescence microscope, micromanipulators, a direct drive linear actuator: a cantilever-type load cell, and a video dimension analyzer (VDA). The test chamber and the microscope are mounted on a vibration isolator. A cell floated in Hanks' balanced salt solution of 37 degrees C is gripped with a pair of micropipettes which have very fine tips (outer diameter = 20 similar to 30 mu m, inner diameter = 3 similar to 5 mu m) and are coated with a cell adhesive, Cell-Tak, at their ends. One of the micropipettes is fixed to the load cell; the other one is attached to the linear actuator which is used to stretch the cell. Load applied to the cell is measured with the load cell, while elongation of the cell is determined with the VDA using the images of the ends of the micropipettes as markers. The measurement accuracy of the load cell was +/- 0.05 mu N. All the fibroblasts tested were firmly attached to the micropipettes during tensile testing, and showed local non-uniform deformation. The maximum load and elongation to failure of the cells were 0.9 +/- 0.2 mu N and 86 +/- 24 mu m, respectively. (C) 1999 Elsevier Science Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据